INDICA PIPES/RIGID PVC PIES F0R SOLVENT
CEMENT JOINING
|
|
INDICA pipes are manufactured in accordance
with Bureau of Iindian Standards specification IS: 4985:2000
and other international standards DIN, BIN, ASTM. Our products
range from 20mm dia to 400mm diameters of solvent cement joning
in different working pressures. (i.e. 2.5, 4, 6, 10kg,&
15kg/cm2
|
INDICA PLUMBING PIPES
|
|
INDICA upvc plumbing pipes are manufactured from 20mm to
50mm diameter confirming to IS:4985:2000 for plumbing in buildings.
|
FEATURES & ADVANTAGES
OF INDICA UPVC PIPES
|
- Non-corrosive and have a glossy smooth internally
and externally
|
- Dielectro-lightic action,do not support the bacterial
growth or encrustation
|
- Non-toxic, economical than other conventional pipes
like stainless steel, brass or GI pipes, etc.
|
- High quality and have greater strength with uniform
wall thickness
|
- Light in weight and easy to handle and install
|
|
APPLICATIONS OF INDICA PIPES
|
- Potable water supplies and drinking water supplies
|
- For lift irrigation & bore wells
|
- These pipes are widely used for irrigation systems
|
- For plumbing and drainage systems in the dwelling
houses.
|
- Electrical industry, construction industry &
chemical industry
|
- For sewerage and drainage
|
- Sewage pipe systems, mainly for aggressive sewage
and in drinking water protection areas
|
- For cableducting in information and telecom sector
|
- Discharge pipes for hospitals and residential buildings
|
- For slurry disposal lines
|
- For dematerialised water lines
|
| INDICA pipes are normally manufactured
in uniform length of 6 metres with self socket at one
side. Varied lengths can be suplied as per customer requirement |
|
PROPERTIES
|
| Specific gravity |
1.41 - 1.46 g/cm3 |
| Coefficient of linear expansion |
5 - 6 x 10-5
mm/m°c |
| Compressive strength |
600 650 kg/cm2 |
| Impact strength |
Complies with IS:4985:2000 |
| Modulus of Elasticity |
3 - 3.8 x 104 kg/cm2 |
| Vical softening point |
80°c |
| Electrical resistance |
1014
ohm cm |
| Tensile strength |
500 - 550 kg/cm2 |
|
DIMENSIONS OF INDICA RIGID
PVC PIPES (IS 4985:2000 EXTRACT)
|
|
Nominal
|
Tolerance
|
Class 1
|
Class 2
|
Class 3
|
Class 5
|
Plumbing
|
|
Outside
|
on outside
|
2.5kgf/cm2
|
|
|
|
pipes
|
|
Diameter
|
Diameter
|
Min
|
Max
|
Min
|
Max
|
Min
|
Max
|
Min
|
Max
|
Min
|
Max
|
|
mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
mm
|
|
20
|
+0.3
|
-
|
-
|
-
|
-
|
-
|
-
|
1.1
|
1.5
|
2.8
|
3.3
|
|
25
|
+0.3
|
-
|
-
|
-
|
-
|
-
|
-
|
1.4
|
1.8
|
2.9
|
3.4
|
|
32
|
+0.3
|
-
|
-
|
-
|
-
|
-
|
-
|
1.8
|
2.2
|
3.4
|
3.9
|
|
40
|
+0.3
|
-
|
-
|
-
|
-
|
1.4
|
1.8
|
2.2
|
2.7
|
3.6
|
4.2
|
|
50
|
+0.3
|
-
|
-
|
-
|
-
|
1.7
|
2.1
|
2.8
|
3.3
|
3.7
|
4.3
|
|
63
|
+0.3
|
-
|
-
|
1.5
|
1.9
|
2.2
|
2.7
|
3.5
|
4.1
|
|
|
|
75
|
+0.3
|
-
|
-
|
1.8
|
2.2
|
2.6
|
3.1
|
4.2
|
4.9
|
|
|
|
90
|
+0.3
|
1.3
|
1.7
|
2.1
|
2.6
|
3.1
|
3.7
|
5.0
|
5.7
|
|
|
|
110
|
+0.4
|
1.6
|
2.0
|
2.5
|
3.0
|
3.7
|
4.3
|
6.1
|
7.1
|
|
|
|
125
|
+0.4
|
1.8
|
2.2
|
2.9
|
3.4
|
4.3
|
5.0
|
6.9
|
8.0
|
|
|
|
140
|
+0.5
|
2.0
|
2.4
|
3.2
|
3.8
|
4.8
|
5.5
|
7.7
|
8.9
|
|
|
|
160
|
+0.5
|
2.3
|
2.8
|
3.7
|
4.3
|
5.4
|
6.2
|
8.8
|
10.2
|
|
|
|
180
|
+0.6
|
2.6
|
3.1
|
4.2
|
4.9
|
6.1
|
7.1
|
9.9
|
11.4
|
|
|
|
200
|
+0.6
|
2.9
|
3.4
|
4.6
|
5.3
|
6.8
|
7.9
|
11.0
|
12.7
|
|
|
|
225
|
+0.7
|
3.3
|
3.9
|
5.2
|
6.0
|
7.6
|
8.8
|
12.4
|
14.3
|
|
|
|
250
|
+0.8
|
3.6
|
4.2
|
5.7
|
6.5
|
8.5
|
9.8
|
13.8
|
15.9
|
|
|
|
280
|
+0.9
|
4.1
|
4.8
|
6.4
|
7.4
|
9.5
|
11.0
|
15.4
|
17.8
|
|
|
|
315
|
+1.0
|
4.6
|
5.3
|
7.2
|
8.3
|
10.7
|
12.4
|
17.3
|
19.9
|
|
|
|
355
|
+1.1
|
5.1
|
5.9
|
8.1
|
9.4
|
12.0
|
13.8
|
19.6
|
22.6
|
|
|
|
400
|
+1.2
|
5.8
|
6.7
|
9.1
|
10.5
|
13.5
|
15.6
|
22.0
|
25.3
|
|
|
|
CONSUMPTION OF SOLVENT CEMENT
|
| O.D. of the pipe in mm |
20 |
25 |
32 |
40 |
50 |
63 |
75 |
90 |
110 |
140 |
160 |
180 |
200 |
225 |
250 |
280 |
315 |
355 |
400 |
| Approx. no. of joints which can be
made per litre of solvent cement |
324 |
270 |
225 |
180 |
130 |
125 |
103 |
79 |
54 |
36 |
27 |
25 |
15 |
12 |
9 |
7 |
5 |
3 |
2 |
|
INDICA UPVC BLUE THREADED
PIPES
|
We manufacture UPVC blue threaded
pipes as per ASTM D - 1785 from 1/2" to 4" nominal
bore
|
|
Schedule 40
|
Schedule 80
|
|
Nominal
|
Outside
|
Wall
|
Working pressure
|
Wall
|
Working pressure
|
|
Bore
|
Diameter
|
Thickness
|
Thickness
|
|
|
|
|
|
Min
|
|
Max
|
Min
|
|
Max
|
|
(inch)
|
(mm)
|
(mm)
|
Mpa
|
Psi
|
(mm)
|
Mpa
|
Psi
|
|
1/2"
|
21.34
|
±
|
0.10
|
2.77
|
-
|
3.10
|
2.07
|
300
|
3.73
|
-
|
4.00
|
2.90
|
420
|
|
3/4"
|
26.67
|
±
|
0.10
|
2.87
|
-
|
3.25
|
1.65
|
240
|
3.91
|
-
|
4.20
|
2.34
|
340
|
|
1"
|
33.40
|
±
|
0.13
|
3.38
|
-
|
3.70
|
1.52
|
220
|
4.55
|
-
|
5.00
|
2.21
|
320
|
|
1 1/4"
|
42.16
|
±
|
0.13
|
3.56
|
-
|
4.00
|
1.24
|
180
|
4.85
|
-
|
5.20
|
1.79
|
260
|
|
1 1/2"
|
48.26
|
±
|
0.15
|
3.68
|
-
|
4.00
|
1.17
|
170
|
5.08
|
-
|
5.55
|
1.65
|
240
|
|
2"
|
60.32
|
±
|
0.15
|
3.91
|
-
|
4.30
|
0.97
|
140
|
5.54
|
-
|
6.00
|
1.38
|
200
|
|
2 1/2"
|
73.02
|
±
|
0.18
|
5.16
|
-
|
5.60
|
1.03
|
150
|
7.01
|
-
|
7.50
|
1.45
|
210
|
|
3"
|
88.90
|
±
|
0.20
|
5.49
|
-
|
6.00
|
0.90
|
130
|
7.62
|
-
|
8.00
|
1.31
|
190
|
|
4"
|
114.30
|
±
|
0.23
|
6.02
|
-
|
6.50
|
0.76
|
110
|
8.56
|
-
|
9.00
|
1.10
|
160
|
|
Note: Working pressure rating
apply to pipes in unthread condition. Threaded pipes will have
half the pressure rating of that of unthreaded pipes.
|
Mpa = Maga Pascal, 1 Mpa - 10Kgf/cm2;
1 Kg/cm2 = 14.5 psi
|
INDICA blue threaded pipes are
normally manufactured in standard lengths of 3mt & 6mt.
Varied lengths can be menufactured according to customer requirements.
|
INDICA CASING PIPES FOR BORE/TUBE
WELL
|
We manufactureUPVC casing pipes
for bore/tueb well confirming to IS: Specification IS:12818
in two categories as follows:
|
- CS type - From 40mm to 250mm nominal diameters
|
- CM type - from 150mm to 250mm
|
- CS (shallow well) pipes suitable for wells with
depths upto 80 metres
|
- CM (medium well) pipes suitable for wells with depth
above 80 metres and upto 250 metres
|
|
FEATURES & ADVANTAGES
|
- High quality and have greater strength with uniform
wall thickness
|
- High impact compressive strength
|
- Light weight and easy to handle and install
|
- Smooth bore, hence excellent flow properties
|
|
PROPERTIES
|
|
|
1.4g/cm2
- 1.45g/cm2
|
- Vicot softening temperature:
|
76°C
|
|
|
50 - 5N/mm2
|
|
|
complies with IS:12818
|
|
|
55N/cm2
|
|
DIMENSIONS OF INDICA UPVC
CASING PIPES (IS:12818)
|
|
Nominal size
|
Outside dia in mm
|
Shallow well(CS)
|
Medium well(CM)
|
|
|
|
|
|
Wall thickness
|
|
|
|
|
|
|
Min
|
Max
|
Min
|
Max
|
|
inch
|
mm
|
mm
|
mm
|
mm
|
|
1 1/2"
|
40
|
48.0
|
48.2
|
-
|
-
|
3.5
|
4.0
|
|
2"
|
50
|
60.0
|
60.2
|
-
|
-
|
4.0
|
4.6
|
|
3"
|
80
|
88.0
|
88.3
|
-
|
-
|
4.0
|
4.6
|
|
4"
|
100
|
113.0
|
113.3
|
-
|
-
|
5.0
|
5.7
|
|
5"
|
125
|
140.0
|
140.4
|
-
|
-
|
6.5
|
7.1
|
|
6"
|
150
|
165.0
|
165.4
|
5.7
|
6.5
|
7.5
|
8.5
|
|
7"
|
175
|
200.0
|
200.5
|
7.0
|
7.8
|
8.8
|
9.8
|
|
8"
|
200
|
225.0
|
225.5
|
7.6
|
8.8
|
10.0
|
11.2
|
|
10"
|
250
|
280.0
|
280.5
|
9.6
|
11.0
|
12.5
|
14.0
|
|
INSTALLATION GUIDELINES
|
- Care should be taken to ensure that UPVC casings
& ribbed screens are lowered properly in a tube
well to ensure proper gravel packing
|
- The gravel packing must be carefully selected depending
upon the soil conditions. The size of slot for the
screens depends on this
|
- Care should be taken to ensure that the gravel packing
sits all around the pipe and there should not be any
bridging.
|
| Care should be taken to ensure no excessive
uneven pressure is generated at the time fo development
and surging. |
|
METHOD OF JOINTING
|
INDICA casing and ribbed and
screen pipes are provided with male threads at one end and female
threads at the other(trapezoidal threads)
|
These joints have a good tensile
strength and can take the suspended weight of the assembly for
greater depths as compared to conventional metal pipe threads.
|
| It must also be noted the bouyancy
when the assembly issubmerged in the water greatly reduces load
on the threaded joints. |